The light box waterway high temperature alarm. Solution: Remove the hose connected to the water channel, and use low-pressure air and alcohol to purge and clean the water channel.
Gripper failure Solution: Adjust the height of the sliding table or the position of the gripper.
The action is stuck. Solution: restart the machine.
Manual origin is impossible. Solution: Check the displacement of one gripper, the displacement of two grippers, and whether the variable pitch positioning plate is stuck in the corresponding position. If not, manually make them stuck in the corresponding position, and then return to the origin.
The action is not in place. Solution: Check if something is stuck. Adjust the gas flow valve.
The exhaust sound is too loud. Solution: Check whether the high-pressure exhaust muffler of the blow molding machine is damaged or falls off.
Inhomogeneous hypoderm of embryonic duct. Treatment method: adjust the position of the embryo bucket.